Search results for "Vision Tests"

showing 10 items of 20 documents

Accuracy and accommodation capability of a handheld autorefractor

2000

Purpose: To determine the accuracy of measurement by the Nikon Retinomax handheld autorefractor and its ability to relax accommodation. Setting: Pediatric Section, Department of Ophthalmology, University of Mainz, Germany. Methods: To perform a series of comparative measurements, autorefractor readings were obtained on healthy young adults (students) and on children aged 2 to 12 years. The autorefractor readings were compared with subjective refractions of the young adults and with cycloplegic retinoscopy of the children. Results: In adults, the accuracy of the handheld autorefractor measurements was comparable to that of conventional tabletop autorefractors. In children, the autorefractor …

AdultAgingmedicine.medical_specialtygenetic structuresOcular refractionRefraction OcularOcular physiologyReference ValuesOphthalmologymedicineHumansChildDioptreRetinoscopyElectronic Data Processingmedicine.diagnostic_testbusiness.industryVision TestsAutorefractorsAccommodation OcularReproducibility of ResultsCycloplegiaRefractive ErrorsSensory SystemsOphthalmologyAutorefractorChild PreschoolOptometrySurgerymedicine.symptombusinessAccommodationJournal of Cataract and Refractive Surgery
researchProduct

Risk factors for high myopia: a 22‐year follow‐up study from childhood to adulthood

2018

PURPOSE To determine the effect of the definition of high myopia on its prevalence and risk factors for high myopia. METHODS A total of 240 myopic schoolchildren (119 boys and 121 girls) at the mean age of 10.9 years (range 8.8-12.8 years) were recruited to a randomized clinical trial of myopia treatment among children from 3rd- and 5th grades of school referred for an eye examination due to poor distant vision and having no previous spectacles. Clinical follow-ups, including refraction with cycloplegia, were conducted annually at 3 years [third follow-up here = clinical follow-up 1, (n = 237)], and thereafter twice at approximately 10-year intervals [clinical follow-ups 2 (n = 179) and 3, …

AdultMalePediatricsmedicine.medical_specialtyYounger ageAdolescentgenetic structuresRefraction Ocularlaw.inventionYoung Adult03 medical and health sciences0302 clinical medicineRandomized controlled trialRisk FactorslawSurveys and QuestionnairesMyopiaPrevalencemedicineHumansChildFinlandRetrospective Studiesmedicine.diagnostic_testbusiness.industryVision TestsFollow up studiesHigh myopiaCycloplegiaGeneral MedicineOdds ratioeye diseasesOphthalmologyEyeglassesEye examinationCohortDisease Progression030221 ophthalmology & optometryFemalesense organsmedicine.symptombusiness030217 neurology & neurosurgeryFollow-Up StudiesForecastingActa Ophthalmologica
researchProduct

An alternative clinical routine for subjective refraction based on power vectors with trial frames.

2016

PURPOSE Subjective refraction determines the final point of refractive error assessment in most clinical environments and its foundations have remained unchanged for decades. The purpose of this paper is to compare the results obtained when monocular subjective refraction is assessed in trial frames by a new clinical procedure based on a pure power vector interpretation with conventional clinical refraction procedures. METHODS An alternative clinical routine is described that uses power vector interpretation with implementation in trial frames. Refractive error is determined in terms of: (i) the spherical equivalent (M component), and (ii) a pair of Jackson Crossed Cylinder lenses oriented …

AdultMaleRefractive errorCorrelation coefficientAdolescentVisual AcuityAstigmatismRefraction Ocular01 natural sciences010309 optics03 medical and health sciencesYoung Adult0302 clinical medicineOptics0103 physical sciencesmedicineHumansPhoropterMathematicsMonocularbusiness.industryOrientation (computer vision)Vision TestsEquipment Designmedicine.diseaseRefractive ErrorsSubjective refractionRefractionSensory SystemsOphthalmologyEyeglasses030221 ophthalmology & optometryFemalebusinessAlgorithmOptometryOphthalmicphysiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)
researchProduct

Diseño de una nueva prueba para medir la función de sensibilidad al contraste con iPad

2015

[EN] Purpose: To introduce a new application (ClinicCSF) to measure Contrast Sensitivity Function (CSF) with tablet devices, and to compare it against the Functional Acuity Contrast Test (FACT). Methods: A total of 42 subjects were arranged in two groups of 21 individuals. Different versions of the ClinicCSF (.v1 and .v2) were used to measure the CSF of each group with the same iPad and the results were compared with those measured with the FACT. The agreements between ClinicCSF and FACT for spatial frequencies of 3, 6, 12 and 18 cycles per degree (cpd) were represented by Bland---Altman plots. Results: Statistically significant differences in CSF of both groups were found due to the change…

AdultMalemedia_common.quotation_subjectVision DisordersVisual performanceFACTDesempeño visualCycles per degreeContrast SensitivityYoung Adultlcsh:OphthalmologyStatisticsHumansContrast (vision)lcsh:QC350-467Tablet devicesDiagnosis Computer-AssistedSensitivity (control systems)Simulationmedia_commonContrast sensitivity functionDispositivos de tabletaVision TestsMiddle AgedFunctional acuity contrast testConfidence intervalTest (assessment)Función de sensibilidad al contrasteiPadlcsh:RE1-994Computers HandheldFISICA APLICADAOriginal ArticleFemaleSpatial frequencyPsychologyEFAClcsh:Optics. LightOptometry
researchProduct

Multichannel functional testing in normal subjects, glaucoma suspects, and glaucoma patients

2012

Purpose.: To evaluate visual function with a novel multichannel functional test named the ATD Multichannel Functional Test. Methods.: This multicenter study had a prospective and cross-sectional design. A total of 186 eyes were included: 42 with glaucoma, 14 glaucoma suspects due to optic nerve characteristics, 25 ocular hypertensives, and 105 normal eyes. All patients performed standard visual fields (Humphrey 24-2) and ATD with eight stimuli configurations: four achromatic (A), two red-green (T), and two blue-yellow (D). To derive main outcome measures, mean sensitivity, mean defect (MD), and pattern standard deviation (PSD) were calculated and compared among groups and types of stimuli w…

AdultMalemedicine.medical_specialty61genetic structuresFunctional testingGlaucomaAudiologyCycles per degreeContrast SensitivityPattern standard deviationOjos--EnfermedadesReference ValuesOphthalmologyOptic Nerve Diseases617MedicineHumansProspective StudiesIntraocular PressureAgedbusiness.industryVision TestsReproducibility of ResultsGlaucomaMiddle Agedmedicine.diseaseNormal limiteye diseasesOphthalmologymedicine.anatomical_structureCross-Sectional StudiesMulticenter studyOftalmologiaEye--DiseasesOptic nerveOftalmologíaFemaleOcular Hypertensionsense organsVisual FieldsbusinessUlls--MalaltiesColor PerceptionOptic disc
researchProduct

Prevalence of refractive errors in the European adult population: the Gutenberg Health Study (GHS).

2014

Objective To study the distribution of refractive errors among adults of European descent. Design Population-based eye study in Germany with15 010 participants aged 35–74 years. Methods The study participants underwent a detailed ophthalmic examination according to a standardised protocol. Refractive error was determined by an automatic refraction device (Humphrey HARK 599) without cycloplegia. Definitions for the analysis were myopia +0.5 D, astigmatism >0.5 cylinder D and anisometropia >1.0 D difference in the spherical equivalent between the eyes. Exclusion criterion was previous cataract or refractive surgery. Results 13 959 subjects were eligible. Refractive errors ranged from −21.5 to…

AdultMalemedicine.medical_specialtyRefractive errorgenetic structuresmedicine.medical_treatmentPopulationVisual AcuityAstigmatismWhite PeopleCellular and Molecular NeuroscienceAge DistributionRefractive surgeryOphthalmologyGermanymedicinePrevalenceHumansVision testProspective StudiesSex DistributioneducationRetinoscopyAnisometropiaAgededucation.field_of_studymedicine.diagnostic_testbusiness.industryVision TestsCycloplegiaMiddle Agedmedicine.diseaseRefractive ErrorsHealth Surveyseye diseasesSensory SystemsOphthalmologyOptometryFemalemedicine.symptombusinessRetinoscopyThe British journal of ophthalmology
researchProduct

Subjective fixation disparity affected by dynamic asymmetry, resting vergence, and nonius bias.

2011

PURPOSE This study was undertaken to investigate how subjectively measured fixation disparity can be explained by (1) the convergent-divergent asymmetry of vergence dynamics (called dynamic asymmetry) for a disparity vergence step stimulus of 1° (60 arc min), (2) the dark vergence, and (3) the nonius bias. METHODS Fixation disparity, dark vergence, and nonius bias were measured subjectively using nonius lines. Dynamic vergence step responses (both convergent and divergent) were measured objectively. RESULTS In 20 subjects (mean age, 24.5 ± 4.3 years, visual acuity, ≥1.0; all emmetropic except for one with myopia, wearing contact lenses), multiple regression analyses showed that 39% of the v…

AdultMalemedicine.medical_specialtyVisual acuityVision Disparitygenetic structuresAdolescentEye Movementsmedia_common.quotation_subjectRestVisual AcuityEmmetropiaAudiologyAsymmetrylaw.inventionFeedbackYoung Adultlawparasitic diseasesmedicineHumansmedia_commonVision BinocularVision TestsVision DisparityMean ageNoniusConvergent and divergent productionFemalemedicine.symptomFixation disparityPsychologyInvestigative ophthalmologyvisual science
researchProduct

Ocular tilt reaction: a clinical sign of cerebellar infarctions?

2009

Ocular tilt reaction (OTR) consists of head tilt, ocular torsion (OT), and skew deviation (SKD) combined with perceptual tilts such as deviations of the subjective visual vertical (SVV). Few case reports have shown that OTR also occurs in patients with cerebellar infarctions.1–4 However, no systematic clinical studies are available on the frequency of signs of OTR in patients with cerebellar lesions. Therefore, the questions arose as to whether OTR is a common clinical sign of an acute cerebellar lesion and whether the time course of its components is similar to those from brainstem infarctions. The cerebellar structures involved in 31 patients were studied in detail elsewhere.5 ### Methods…

Brain InfarctionMalemedicine.medical_specialtyCerebellar lesionsSensitivity and SpecificityCentral nervous system diseaseCerebellar DiseasesTilt-Table Testmedicine.arteryCerebellummedicineSkew deviationHumansAgedAged 80 and overmedicine.diagnostic_testVascular diseasebusiness.industryVision TestsReproducibility of ResultsMiddle AgedVestibular Function Testsmedicine.diseaseSurgeryAnterior inferior cerebellar arteryElectronystagmographyFemaleNeurology (clinical)RadiologyOcular tilt reactionBrainstembusinessNeurology
researchProduct

Colorimetric Characterization of Mobile Devices for Vision Applications

2015

Purpose: Available applications for vision testing in mobile devices usually do not include detailed setup instructions, sacrificing rigor to obtain portability and ease of use. In particular, colorimetric characterization processes are generally obviated. We show that different mobile devices differ also in colorimetric profile and that those differences limit the range of applications for which they are most adequate. Methods: The color reproduction characteristics of four mobile devices, two smartphones (Samsung Galaxy S4, iPhone 4s) and two tablets (Samsung Galaxy Tab 3, iPad 4), have been evaluated using two procedures: 3D LUT (Look Up Table) and a linear model assuming primary constan…

Computer scienceColor reproductionColorSoftware portabilityRange (statistics)HumansComputer visionIndependence (probability theory)ÓpticaColor differencebusiness.industryVision TestsUsabilityColorimetric characterizationOphthalmologyScreenComputers HandheldLookup tableLinear Models3D lookup tableColorimetryArtificial intelligenceSmartphonebusinessTabletMobile deviceOptometry
researchProduct

Effect of Decentration on the Optical Quality of Two Intraocular Lenses

2016

To analyze the effect of decentration on the optical quality of two diffractive-refractive intraocular lenses, a bifocal and a trifocal, when displaced laterally (horizontal direction) from the center.The AT LISA 809M IOL (+3.75 D add) with two main foci and the AT LISA tri 839MP intraocular lens with three main foci (Carl Zeiss Meditec AG, Jena, Germany) were analyzed. The optical quality of the intraocular lenses was measured with the PMTF (power and modulation transfer function [MTF] measurement for refractive and diffractive intraocular lenses) optical bench (Lambda-X, Nivelles, Belgium). The optical quality of the lenses was evaluated by the MTF at different object vergences, the avera…

Lenses IntraocularOptics and Photonicsbusiness.industryVision TestsProsthesis DesignRefraction OcularRefractionOptical quality03 medical and health sciencesOphthalmologyOcular physiology0302 clinical medicineOpticsIntraocular lenses030221 ophthalmology & optometryHumansProsthesis designOptometryVision testbusinessVision Ocular030217 neurology & neurosurgeryGeologyOptometryOptometry and Vision Science
researchProduct